Sound

CHRIS YOUNG – AUDIO ENGINEER
chris@theindependentsf.com

Mix Position

Both FOH Audio and Lighting are located in an elevated 15′ x 9′ “crows nest” accessible via the VIP mezzanine. This private tech space is 9 feet above the main floor, positioned between Left and Right Mains and approximately 50′ from the Down Stage Edge.

PA SYSTEM

(8) d&b audiotechnik V Series Line Array – 4 Per Side (2 x V12 / 2 x V8)
(6) d&b audiotechnik V Series Subs – 6 total – Under Stage – Along the DS Edge.

FRONT OF HOUSE SYSTEM

(1) Midas Legend 3000 – 48 mono / 4 stereo
(1) LA Audio Stereo 31 Band Stereo EQ – Inserted on Left/Right
(1) Daking Audio FET III Compressor – Inserted on Left/Right
(1) Klark Teknik DN360 31 Band EQ for Subs (Fed by Matrix)

OUTBOARD COMPS & GATES

(1) Drawmer DL 441 – 4ch Compressor
(1) BSS DPR404 – 4ch Compressor
(1) KT DN500 Stereo/Dual Mono Compressor / Expander
(3) DBX 160
(2) DBX 166
(1) Symetrix 525 – Stereo/Dual Mono Compressor/Gate
(2) Klark Teknik DN514 4 Channel Gates
(1) ART Pro Stereo/Dual Mono Tube Compressor

OUTBOARD EFFECTS

(1) Lexicon PCM-80 Reverb
(1) Lexicon MX400 Multi Verb
(1) TC Electronics M1 Multi Effects Processor
(1) TC Electronic D-Two Delay

MONITOR SYSTEM

(1) Digidesign SC48 – 16 Outputs – Stock Plug-in Package
(5) L’Acoustic LA8 Amplifiers – 10 mixes total – (1 less for cue)
(8) L’Acoustic X15 HiQ Bi-Amped Wedges
(4) L’Acoustic X12 Passive Wedges
(3) L’Acoustic SP15 Subs.

MICROPHONES AND DI’s

(1) AKG D112
(1) Sennheiser 602
(1) EV ND 868
(1) ADX 51 – SDC
(3) EV ND 468
(1) Shure Beta 91
(1) Shure Beta 56a
(2) Shure Beta 58
(4) Shure Beta 57a
(9) Shure SM58
(10) Shure SM57
(2) Shure SM 81 condenser
(2) Octavia 319 LD condenser
(6) Sennheiser 604
(4) Sennheiser 835
(2) Sennheiser 609
(3) Sennheiser 421
(1) Audio Technica MB4000 condenser
(5) Klark Technic active DI
(3) DOD passive DI
(3) Whirlwind passive DI
(3) Radial Passive DI
(1) Radial Passive Stereo DI
(1) GT Passive DI

GUEST LINES

(2) 22AWG CAT6 Ethercon Lines w/ Neutrik Barrels from Stage to FOH (2) Standard Cat5 Cables from Stage to FOH

Guest consoles, FOH racks, etc. must reside in the upstairs FOH booth. Consoles are not permitted to be on the ground floor.

50a 3 phase camlock for additional sound power

*ALL PA DRIVE LINES FROM FOH ONLY*

SPL POLICY

The Independent is located in the highly residential Alamo Square neighborhood. The city has given us an internal SPL limit of 117 dbC, measured on the ground floor under the sound board. This limit will be enforced by our staff and is non-negotiable.

Power

The Independent has three-phase power running into the club. Audio and lights will be on separate, isolated legs.

50A 3-phase cam-in isolated guest service for audio.

NOT FOR DISTRIBUTION